Display: 5999 counts backlit LCD
Over-range Alert
Polarity: Automatic
Data Hold
Low Battery indication
Non-contact Voltage Detection (NCV)
Fuses: mA range; 630mA/250V fast blow fuse, 10A range no fuse
CATII 600V protection
DC Voltage: 600.0mV/6.000V/60.00V/600.0V
Accuracy: ±(0.5% reading + 2 digits)
AC Voltage (40~400Hz): 6.000/60.00/600.0V
Accuracy: ±(0.8% reading + 3 digits)
DC Current: 600.0µA/6000µA/60.00mA/600.00mA/6A/10A
Accuracy: ±(1.0% reading + 4 digits)
AC Current (40 to 400Hz): 600.0µA/6000µA/60.00mA/600.00mA/6A/10A
Accuracy: ±(1.2% reading + 5 digits)
Capacitance: 9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999mF
Accuracy: ±(3.0% reading+ 10 digits)
Resistance: 600.0Ω/60.00kΩ/60.00kΩ/600.0kΩ/6.000MΩ/60.00MΩ
Accuracy: ±(1.2% reading + 4 digits)
Frequency: 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kZ/9.999MHz
Accuracy: ± (0.3% reading + 4 digits), Sensitivity : 3.0V RMS
Temperature (Requires type K thermocouple) : 20° to 1000°C
Accuracy: -20° to 1000°C; ±(1% rdg + 5 digits) (probe accuracy not included)
Diode Test: Test current of 1mA maximum, open circuit voltage 3.2V DC typical
Continuity Check: Audible signal will sound if the resistance is less than approximately <40±5Ω
Input Impedance: 10MΩ (V AC/DC)
| Brand | Metravi |
|---|---|
| Colour | Blue-Black |
| Warranty | One year against manufacturing defects |
| Model | XB-33A |
| Display | Backlit LCD |
| Auto Ranging | Auto Ranging |
| T-RMS | T-RMS |
| Polarity | Automatic |
| Data Hold | Data Hold |
| Low Battery Indication | Low Battery Indication |
| Overload Indication | Overload Indication |
| NCV Detection | Non-contact Voltage Detection |
| DC Voltage Range | 0-600mV/6V/60V/600V |
| DC Voltage Accuracy | ±0.5% |
| AC Voltage Range | 0-6V/60V/600V |
| DC Current Range | 0-600uA/6000uA/60mA/600mA/6A/10A |
| DC Current Accuracy | ±1% |
| AC Current Range | 0-600uA/6000uA/60mA/600mA/6A/10A |
| Resistance Range | 0-600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ |
| Resistance Accuracy | ±1.2% |
| Capacitance Range | 0-9.999nF/99.99nF/999.9nF/9.999uF/99.99uF/999.9uF/9.999mF |
| Frequency Range | 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz |
| Frequency Accuracy | ±0.3% |
| Duty Cycle Range | 1% to 99% |
| Temperature Range | -20°C to 1000°C |
| Temperature Accuracy | ±1.0% |
| Diode & Continuity | Diode & Continuity test |
| Power Source | Battery Operated |
| Battery Type | Alkaline |
| Battery Size | AAA |
| No of Batteries | 2 |
| Sampling Time | 3 times/sec |
| Certifications | CAT II 600V |


Reviews